Extreme Networks AC Power Supply XT 300w 10930A - Extreme Networks Accessories

Extreme Networks AC Power Supply XT 300w 10930A - Extreme Networks Accessories

Regular price
₱20,000.00
Sale price
₱20,000.00
Regular price
Sold out
Unit price
per 

 

Extreme Networks Power Supply module - AC 85-264 V - 300 Watt - Extended Temperature Range from -10 to +50 degrees Celsius - Front-to-Back airflow - for ExtremeSwitching X460 (Part # 10930A)

Technical Specifications

Physical Specifications
Dimensions Height: 1.57 inches (4.0 cm)Width: 3.15 inches (8.0 cm)
Depth: 9.5 Inches (24.1 cm)
Weight 2.30 lb (1 kg)
Power Specifications
Voltage input range 85 to 264 V
Nominal input ratings 100 to 240 V, 50 to 60 Hz, 5 A
Nominal input current at full loads 4.2 A @ 90 V (low-line)1.7 A @ 230 V (high-line)
Line frequency range 47 to 63 Hz
Maximum inrush current 30 A
Output 12 V, 25 A max, 300 Watts3.3 V, 3.03 A max, 10 Watts
Power supply input socket IEC 320 C14
Power cord input plug IEC 320 C13
Power supply cord gauge 18 AWG (0.75 mm2) up to 6 feet or 2 metersor
16 AWG (1.0 mm2) over 6 feet
Efficiency Low Line: 85% at 50% load and 88% at 100% loadHigh Line: 86% at 50% load and 89% at 100% load
Environmental Specifications
Operating temperature –10°C to 50°C (14°F to 122°F), normal operation
Storage temperature -40°C to 70°C (-40°F to 158°F)
Operating humidity 20% to 90% relative humidity, non-condensing
Operational shock 30 m/s2 (3 G)
Dimensions Height: 1.57 inches (4.0 cm)Width: 3.15 inches (8.0 cm)
Depth: 9.14 Inches (23.2 cm)
Weight 1.5 lb (0.68 k)
Summit 300 W DC Power Supply (Model 10933)
Power Specifications
Nominal Input Rating #ERROR!
DC Voltage Input Range 18 V — 72 V
Maximum Input Amperages 14.6A at 24 V7.3A at 48 V
4.8A at 72 V
Inrush Current 35A at 72 V peak
Minimum wire size 14 AWG (1.5 mm2) copper stranded
DC Output Power (W) 300 W
Environmental Specifications
Operating temperature 0°C to 50°C (32°F to 122°F), normal operation
Storage temperature -40°C to 70°C (-40°F to 158°F)
Operating humidity 20% to 90% relative humidity, non-condensing